Sizes available: 316 Stainless Steel
2" thru 12" with 1/8" Thickness
8" thru 20" with 1/4" Thickness
16" thru 24" with 3/8" Thickness
▪CMTRS – Certified Mill Test Reports Available
▪Manufactured to exceed all AGA and API requirements.
▪Universally rated for ANSI 150 to 2500 orifice fittings
Seal Rings Sizes available:
HNBR material 2" thru 20"
Teflon material 2" thru 12"
FKM material 2" thru 20"
Nitrile material 2" thru 24"
* HNBR , FKM & Nitrile seal rings are also available in 14.3 New Style
Available Sizes:
316 SS Flange Type
2" thru 16" Sch40 & Sch80
316 SS Pin Type
2" thru 4" Sch40 & Sch80
316 SS Long Pin Type
2" thru 4" Sch40 & Sch80
Features: Sizes range from 1/16” to 2” | 2 MM THROUGH 50 MM
Ham-let tube fitting is a mechanism used both to seal and to grip tubing. The mechanical advantage and geometry of this kind of fitting produces a leak-tight assembly .
Ham-let tube fittings have been carefully manufactured to withstand the persistent demands for high-performance fluid system.
Features: Sizes range from 1/16” to 2”
Fittings are properly packaged with the exposed threads protected to ensure they are not damaged during delivery
All pipe threads meet the requirements of ASME/ANSI B1.20.1 (1983) for tapered pipe threads (NPT)
Working pressures are calculated in accordance with Power Piping Code ANSI B 31.1, Refiner Piping Code ASME/ANSI B 31.3 and section VIII of ASME Boiler & Pressure Vessel Code
Features: Sizes range from 1/4” to 1”
The HAM-LET ‘’UH’’ Series is designed for ultra-vacuum systems. Following are some of its special features:
Finger-tight assembly (with knurled nut)
Easy removal, easy repositioning in a system
Helium leak tested to 4X10-9 ATM.cc/sec
Maximum temperature: 242°Cc
Available factory assembly for many HAM-LET Valves: Ball Valve, Needle Valve, Diaphragm Valve, Filter, Check Valve
All metal parts are 316 Stainless Steel, O-ring - Fluorocarbon FKM.
METAL HOSES
PTFE HOSES
RUBBER HOSES
NYLON HOSES
PFA HOSES
FFEATURES:
Soft seat (PEEK) Non-rotating stem
MAWP 3000 Psi (206 Bar)
Temperature working range -20°C to 122°C (-4°F to 252°F)
Rupture disc pressure ratings: 1900 Psi (131 Bar), 285 (196 Bar)
Handle design prevents contaminants from entering into valve's critical, functional parts
Orifice size: 5.6 mm (0.218 inch)
Flow Coefficient (Cv): 0.53
Comply with TPED (2010/35/EU) as standard
FEATURES
Working pressure rating: up to 3,000 psig (206 bar).
Interchangeable and intermixable with major Instrumentation
Quick Connectors available in the market.
Fluorocarbon FKM O-Rings as standard, O-rings with other materials are available.
Smooth and safe connection between the QC-LOK® Connector valves is reached by a simple pushing operation due to a smart heavy-duty locking mechanism.
The QC-LOK® Instrumentation Quick Connectors validation tests are based on ANSI/B93.51M–1980
FEATURES
Fugitive Emission Free Valve
Encapsulated Cylindrical Stem design
On/off-service, one-piece Cylindrical Valve with
2-way pattern Stainless Steel construction
Allows bi-directional flow in 2-way straight pattern
One-piece Cylindrical Stem ensures alignment of stem and orifice
Max working pressure 2500 psi (206 bar)
Max working temperature 140ºF (60ºC)
Variety of end connection and sizes available
Variable end connection types and sizes from 1/4” to 1/2” (6mm to 12mm)
TBV FEATURES
On/Off-service ball valve with 2-way pattern
Diverter, selector and on/off-service ball valve with 3-way pattern
MAWP* 10,000 psi (689 bar) with PEEK seats MAWT* 446ºF (230ºC) with PEEK seats
Operation with colored Nylon handles, metal handle, color anodized aluminum ISLT** (locking device) handles
Low-operating torque
Easy panel mounting
Electric and pneumatic actuators available
FEATURES
On/Off and Metering service
• PFA Encapsulated Ball Stem design
• Panel Mounting as standard
• MAWP 2000 psi (137 Barg)
• MAWT 300°F (150°C)
• End Connections: LET-LOK 1/16”, 1/8”, 1/4”, 3/8”;
• FNPT 1/8”; MNPT 1/8”; Male Face Seal 1/4”
• 1°,3° and 5° Stem Taper for required flow control
• Stem with Stopper shoulder for long life service a description about this item
Electronic Gauge Pressure, Gauge Pressure, Pressure Measurement
Description - The 3051 Series SMART Transmitters are offered in a variety of configurations for differential, gauge, liquid-level, flow and specific gravity measurement applications.
Description - The 3051S Series SMART Pressure Transmitters are offered in a variety of configurations for differential, gauge, liquid-level, flow and specific gravity measurement applications
Typical Application:
3051S_CA: Absolute Pressure
3051S_CD: Differential Pressure for flow or level measurement
3051S_CG: Gauge Pressure
3051SAL: Flanged-mounted Liquid Level for open- or closed-tank application
3051S_TA: Direct Mount Absolute Pressure
3051S_TG: Direct Mount Gauge Pressure
Description - The 3051 Series SMART Transmitters are offered in a variety of configurations for differential, gauge, liquid-level, flow and specific gravity measurement applications.
Differential Pressure, Electronic Differential Pressure, Pressure Measurement
Description - The 1151 Alphaline Pressure Transmitters are offered in a variety of configurations for differential, gauge, absolute, liquid-level, flow and specific gravity measurement applications.
Absolute Pressure, Electronic Absolute Pressure, Pressure Measurement
Description - The 1151 Alphaline Pressure Transmitters are offered in a variety of configurations for differential, gauge, absolute, liquid-level, flow and specific gravity measurement applications.
The 3144P SMART Temperature Transmitters accept a user-selectable RTD, thermocouple, millivolt, or ohm input and transmit a proportional digital HART-based electrical signal.
Complete Transmitter assembly | Thermowell | RTD's
Description - The 3144D SMART Temperature Transmitters accept a user-selectable RTD, thermocouple, millivolt, or ohm input and transmit a proportional digital HART-based electrical signal.
Thermowells are manufactured from solid 304 and 316 stainless steel barstock and available in many threaded combinations. The versatility of this design allows fabricators to easily install the thermowells in many piping configurations. With over 80,000 parts in stock, we are able to ensure quick delivery on 2″ through 10″ parts. Custom sizes can be ordered and typically ready to ship in 5-7 business days
EDGE P FCX-AII V5 Series
TECHNICAL SPECIFICATIONS
• Pressure ranges from 1.6 kPa abs up to 10000 kPa abs (0.23206 to 1450.38 psi abs)
• Accuracy: ±0.2% (option: ±0.1%)
• Stability: ±0.2% of URL for 10 years
• Output: 4-20 mA / HART or Foundation Fieldbus
• Programmable output linearization in up to 14 points
• Burnout current functionality compliant with NAMUR NE43
• Dry calibration without reference pressure
TECHNICAL SPECIFICATIONS
• Pressure ranges from 0.32 kPa up to 50000 kPa (0.04641 to 7251.89 psi)
• Accuracy: ±0.065% for differential and gauge pressure models and ±0.2% for absolute pressure models
• Stability: ±0.2% of URL for 10 years
• Output: 4-20 mA / HART or Foundation Fieldbus
• Programmable output linearization in up to 14 points
• Burnout current functionality compliant with NAMUR NE43
• Dry calibration without reference pressure
TECHNICAL SPECIFICATIONS
•Pressure ranges from 0.1 kPa up to 20000 kPa (0.0145 to 2900.75 psi)
•Accuracy: ±0.065% (option: ±0.04%)
•Stability: ±0.1% of URL for 10 years
•Output: 4-20 mA (linear or square root) / HART or Foundation Fieldbus
•Programmable output linearization in up to 14 points
•Burnout current functionality compliant with NAMUR NE43
•Low flow cut-off
•Dry calibration without reference pressure
TECHNICAL SPECIFICATIONS
• Pressure ranges from 10 mmH2O up to 300000 mmH2O (0.3937 to 11811 inH2O)
• Accuracy: ±0.165% (option: ±0,1%)
• Stability: ±0.2% of URL for 10 years
• Output: 4-20 mA / HART or Foundation Fieldbus
• Programmable output linearization in up to 14 points
• Burnout current functionality compliant with NAMUR NE43
• Dry calibration without reference pressure
TECHNICAL SPECIFICATIONS
• Pressure ranges from 1.3 kPa up to 50000 kPa (0.18855 to 7251,89 psi)
• Accuracy: ±0.065% (option: ±0.04%)
• Stability: ±0.1% of URL for 10 years
• Output: 4-20 mA / HART or Foundation Fieldbus
• Programmable output linearization in up to 14 points
• Burnout current functionality compliant with NAMUR NE43
• Dry calibration without reference pressure
TECHNICAL SPECIFICATIONS
•Pressure ranges from 8.125 kPa abs up to 3000 kPa abs (1.1784 to 435.11 psi abs)
•Accuracy: ±0.2%
•Stability: ±0.2% of URL for 10 years
•Output: 4-20 mA / HART or Foundation Fieldbus
•Programmable output linearization in up to 14 points
•Burnout current functionality compliant with NAMUR NE43
•Dry calibration without reference pressure
TECHNICAL SPECIFICATIONS
•Pressure ranges from 8.125 kPa up to 10000 kPa (1.1784 to 1450.38 psi)
•Accuracy: ±0.1%
•Stability: ±0.2% of URL for 10 years
•Output: 4-20 mA / HART or Foundation Fieldbus
•Programmable output linearization in up to 14 points
•Burnout current functionality compliant with NAMUR NE43
•Dry calibration without reference pressure
TECHNICAL SPECIFICATIONS
•Pressure ranges from 8.125 kPa up to 10000 kPa (1.1784 to 1450.38 psi)
•Accuracy: ±0.1% for FKP and ±0.2% for FKH
•Stability: ±0.2% of URL for 10 years
•Output: 4-20 mA / HART or Foundation Fieldbus
•Programmable output linearization in up to 14 points
•Burnout current functionality compliant with NAMUR NE43
•Dry calibration without reference pressure
Copyright © 2023 SKCO LLC - All Rights Reserved.